SELECTING A MOUNTING LOCATION
1. Give consideration to the weight of the unit when operating (filled with water). Operating weights
of the QC7I Systems are:
• Single System - 9 lbs. (4.0 kg.)
• Twin System - 19 lbs. (8.5 kg)
• Triple System - 27 lbs. (12 kg)
• Quad System - 36 lbs. (20 kg)
2. The location should allow for:
Minimum clearance of 2-1/2” under the cartridge(s) so it can be lowered for removal and
replacement.
• Adequate space for “in” and “out” water line connections.
Be near a drain for flushing and near a 110V outlet if the accessory (sold separately) Everguard
Low Pressure Alarm is used. See Figures 1-8.
3. If used in conjunction with the SR-X feeder, the SR-X should be mounted after the QC7I Series
Filter and as near the equipment as possible. If possible, keep at least 6” available to the left and
the right of the QC7I System in the event poor quality water conditions require the installation of
the optional Everpure E-Series Prefilter.
WARNING: Do not use the MH cartridge in conjunction with the SR-X.
OPERATING SPECIFICATIONS*
Combined Model Name
Replacement
Cartridge Flow Rate Capacity
QC7I Single - MC MC 1.67 gpm (6.3 lpm) 9,000 gal (34,000 L)
QC7I Single - MC
2
MC
2
1.67 gpm (6.3 lpm) 9,000 gal (34,000 L)
QC7I Single - MH MH 1.67 gpm (6.3 lpm) 9,000 gal (34,000 L)
QC7I Single - MH
2
MH
2
1.67 gpm (6.3 lpm) 9,000 gal (34,000 L)
QC7I Single - TO
TO 1.5 gpm (18.9 lpm) 30,000 gal (113,550 L)
QC7I Single - CV CV 1.67 gpm (6.3 lpm) 7,500 gal (28,390 L)
QC7I Single - XCV XCV 1.67 gpm (6.3 lpm) 10,000 gal (37,850 L)
QC7I Single - XC XC 1.67 gpm (6.3 lpm) 12,000 gal (45,420 L)
QC7I Single - XC
2
XC
2
1.67 gpm (6.3 lpm) 12,000 gal (45,420 L)
QC7I Single - 7CB5 7CB5 2.5 gpm (9.4 lpm) 10,000 gal (37,850 L)
QC7I Single - 7CB5-K 7CB5-K 2.5 gpm (9.4 lpm) 10,000 gal (37,850 L)
QC7I Single - 7CB5-S 7CB5-S 2.5 gpm (9.4 lpm) 10,000 gal (37,850 L)
Combined Model Name
Replacement
Cartridge Flow Rate Capacity
QC7I Twin - MC
MC 3.3 gpm (12.6 lpm) 18,000 gal (68,000 L)
QC7I Twin - MC
2
MC
2
3.3 gpm (12.6 lpm) 18,000 gal (68,000 L)
QC7I Twin - MH
MH 3.3 gpm (12.6 lpm) 18,000 gal (68,000 L)
QC7I Twin - MH
2
MH
2
3.3 gpm (12.6 lpm) 18,000 gal (68,000 L)
QC7I Twin - TO
TO 3.0 gpm (37.8 lpm) 60,000 gal (227,100 L)
QC7I Twin - CV CV 3.3 gpm (12.6 lpm) 15,000 gal (56,780 L)
QC7I Twin - XCV XCV 3.3 gpm (12.6 lpm) 20,000 gal (75,700 L)
QC7I Twin - XC
XC 3.3 gpm (12.6 lpm) 24,000 gal (90,840 L)
QC7I Twin - XC
2
XC
2
3.3 gpm (12.6 lpm) 24,000 gal (90,840 L)
QC7I Twin - 7CB5
7CB5 5.0 gpm (18.9 lpm) 20,000 gal (75,700 L)
QC7I Twin - 7CB5-K 7CB5-K 5.0 gpm (18.9 lpm) 20,000 gal (75,700 L)
QC7I Twin - 7CB5-S 7CB5-S 5.0 gpm (18.9 lpm) 20,000 gal (75,700 L)
Figure 1 – Single System
EV3024-87D DE05
Installation and Operation Guide
QC7I Series Water Filters
Manufactured by Everpure
Figure 2 – Twin System
Figure 4 – Quad System
Figure 3 – Triple System
Vue de la page 0
1 2 3 4

Résumé du contenu

Page 1 - QC7I Series Water Filters

SELECTING A MOUNTING LOCATION1. Give consideration to the weight of the unit when operating (filled with water). Operating weights of the QC7I System

Page 2 - INSTALLATION

Combined Model NameReplacement Cartridge Flow Rate CapacityQC7I Triple - MCMC 5.0 gpm (18.9 lpm) 27,000 gal (102,000 L)QC7I Triple - MC2MC25.0 gpm (18

Page 3 - FLUSHING

CARTRIDGE CHANGE PROCEDUREEverpure Carbon Filter Cartridge Change1. Shut off power to equipment. Shut off inlet water ahead of system.2. Open flush

Page 4 - LIMITED WARRANTY

For sales, replacement components, and service, contact your Everpure dealer or:Everpure, LLC: 1040 Muirfield Drive • Hanover Park, Illinois 60133 • 80